Safety

Last updated 2026-11-27

This page lists the hazards of handling and running the drive, and the protective functions the drive has. Use it as input to the risk assessment of your own device; it does not replace one.

Protective functions

Function What it does Not defined yet
Torque off on fault On a fault the drive switches torque off. The joint then moves freely. Fault list, reaction time
Safe torque off (STO) Hardware function that switches torque off. Designed toward IEC 61800-5-2. Not certified. Input type, wiring, response time
Friction compensation The firmware adds torque to cancel the drive's own friction. Limits
Local safety reflexes The drive reacts by itself, without waiting for the host, to conditions set in the firmware. Conditions and reactions
Passivity limits The firmware limits the energy the drive puts into the joint. Limit values
Update load interlock The updater refuses to flash a drive whose joint is holding load. Detection method
Interlock loop (HVIL) A hardwired PWM loop runs through every drive in the device. If the loop opens anywhere (damaged drive, cut cable, unplugged connector), every drive on the loop goes to its safe state, without waiting for CAN. Loop start, pin numbering, reaction time, re-arm, safe-state behaviour per device

None of these functions is certified. The firmware functions support the protective measures of your device; they do not replace them.

Handling and assembly

Warning The magnets pull the rotor onto the stator with roughly 100 kg of force on a single-row drive, and more on a two-row drive. Never separate or lower the rotor by hand. Use only the assembly fixture described in Mechanical integration. Fingers caught between rotor and stator can be crushed.

A free joint after a fault

When the drive switches torque off after a fault, the joint moves freely. The drive does not brake or hold it.

Design your device so that a free joint is acceptable in every posture and at every point of every motion. In an exoskeleton, check each phase of a movement in which the wearer relies on the joint torque, and decide what holds the wearer if that joint goes free.

Safe torque off

The STO function is designed toward IEC 61800-5-2 and is not certified. Do not count it as part of a certified safety function. Its electrical interface is TBD; see Electrical and CAN wiring.

Interlock loop (HVIL)

Every drive has a 2-pin HVIL connector with a loop input and a loop output. The loop carries a PWM signal. Wire the drives in a daisy chain and close the loop at the last drive.

The loop start, connector part, pin numbering, reaction time, re-arm behaviour and the safe state the drives go to are TBD. For an exoskeleton, decide whether a free joint or a controlled lowering is the safe state in each posture; see A free joint after a fault. Wiring, bench testing with a jumper and loop checks are in Interlock loop (HVIL).

Electrical

Heat

The drive reports its temperature. Temperature limits and housing surface temperatures are not measured yet. Until they are published, do not let the housing touch skin while the drive is powered.

Firmware updates

Warning Do not update a device while a person wears it or while any joint carries load. A drive that is being updated does not hold its joint.

The updater refuses to flash a drive whose joint is holding load. See Firmware updates.

Standards

Standard Status
IEC 61800-5-2, safe torque off Designed toward; not certified
Other certifications None