Safety
This page lists the hazards of handling and running the drive, and the protective functions the drive has. Use it as input to the risk assessment of your own device; it does not replace one.
Protective functions
| Function | What it does | Not defined yet |
|---|---|---|
| Torque off on fault | On a fault the drive switches torque off. The joint then moves freely. | Fault list, reaction time |
| Safe torque off (STO) | Hardware function that switches torque off. Designed toward IEC 61800-5-2. Not certified. | Input type, wiring, response time |
| Friction compensation | The firmware adds torque to cancel the drive's own friction. | Limits |
| Local safety reflexes | The drive reacts by itself, without waiting for the host, to conditions set in the firmware. | Conditions and reactions |
| Passivity limits | The firmware limits the energy the drive puts into the joint. | Limit values |
| Update load interlock | The updater refuses to flash a drive whose joint is holding load. | Detection method |
| Interlock loop (HVIL) | A hardwired PWM loop runs through every drive in the device. If the loop opens anywhere (damaged drive, cut cable, unplugged connector), every drive on the loop goes to its safe state, without waiting for CAN. | Loop start, pin numbering, reaction time, re-arm, safe-state behaviour per device |
None of these functions is certified. The firmware functions support the protective measures of your device; they do not replace them.
Handling and assembly
Warning The magnets pull the rotor onto the stator with roughly 100 kg of force on a single-row drive, and more on a two-row drive. Never separate or lower the rotor by hand. Use only the assembly fixture described in Mechanical integration. Fingers caught between rotor and stator can be crushed.
- Do not remove the 12 × M3 countersunk screws in the back plate.
- Use the 3 × M5 holes in the output face only for the assembly fixture.
- The drive weighs about 2.2 kg (single row) or 3.4 kg (two rows), estimated. Support it while you fit the screws.
A free joint after a fault
When the drive switches torque off after a fault, the joint moves freely. The drive does not brake or hold it.
Design your device so that a free joint is acceptable in every posture and at every point of every motion. In an exoskeleton, check each phase of a movement in which the wearer relies on the joint torque, and decide what holds the wearer if that joint goes free.
Safe torque off
The STO function is designed toward IEC 61800-5-2 and is not certified. Do not count it as part of a certified safety function. Its electrical interface is TBD; see Electrical and CAN wiring.
Interlock loop (HVIL)
Every drive has a 2-pin HVIL connector with a loop input and a loop output. The loop carries a PWM signal. Wire the drives in a daisy chain and close the loop at the last drive.
- If the loop opens at any point, every drive on it goes to its safe state. A damaged drive or a cut cable therefore stops the whole device, not only the joint that failed.
- The loop works without CAN and without the host. It also covers a drive that can no longer send messages.
- Each drive reports the loop state on CAN, so the host can tell where the loop opened.
The loop start, connector part, pin numbering, reaction time, re-arm behaviour and the safe state the drives go to are TBD. For an exoskeleton, decide whether a free joint or a controlled lowering is the safe state in each posture; see A free joint after a fault. Wiring, bench testing with a jumper and loop checks are in Interlock loop (HVIL).
Electrical
- The drive runs from 48 V DC.
- When the joint is back-driven or braked, the drive returns energy to the supply and the line voltage can rise. See Electrical and CAN wiring.
- Turning the output by hand can produce a voltage on the supply terminals, also with the supply switched off.
Heat
The drive reports its temperature. Temperature limits and housing surface temperatures are not measured yet. Until they are published, do not let the housing touch skin while the drive is powered.
Firmware updates
Warning Do not update a device while a person wears it or while any joint carries load. A drive that is being updated does not hold its joint.
The updater refuses to flash a drive whose joint is holding load. See Firmware updates.
Standards
| Standard | Status |
|---|---|
| IEC 61800-5-2, safe torque off | Designed toward; not certified |
| Other certifications | None |