Electrical and CAN wiring
This page covers the 48 V supply, the CAN bus wiring and the safe torque off input. The connector and pin-out are not defined yet.
Electrical interface
| Item | Value |
|---|---|
| Supply voltage, nominal | 48 V DC |
| Supply voltage range | TBD |
| Supply current, continuous and peak | TBD |
| Power connector | TBD |
| Signal connector | TBD |
| CAN | CAN FD; classic CAN at 1 Mbit/s |
| CAN FD data bit rate | TBD |
| Built-in CAN termination | TBD |
| Safe torque off input | Electrical interface TBD. Designed toward IEC 61800-5-2, not certified. |
| HVIL connector | One 2-pin connector: loop IN and loop OUT. PWM signal, daisy-chained through all drives. Part TBD. See Interlock loop (HVIL). |
Pin-out
| Signal | Connector | Pin |
|---|---|---|
| Supply + (48 V) | TBD | TBD |
| Supply − (0 V) | TBD | TBD |
| CAN_H | TBD | TBD |
| CAN_L | TBD | TBD |
| CAN ground | TBD | TBD |
| HVIL loop IN | HVIL connector, pin TBD | TBD |
| HVIL loop OUT | HVIL connector, pin TBD | TBD |
| Safe torque off | TBD | TBD |
| Cable shield | TBD | TBD |
Connect the supply
- Switch the supply off.
- Fit a fuse in the positive line, close to the supply. Fuse rating: TBD.
- Connect the drive.
- Switch the supply on.
Do not plug the drive into a supply that is already on.
Energy returned to the supply
When the joint is back-driven, or when the drive brakes the joint, the motor acts as a generator and returns energy to the 48 V line. A bench supply that cannot sink current lets the line voltage rise. Use one of these:
- a supply that can sink current,
- a battery,
- a voltage clamp (brake resistor and switch) on the 48 V line.
How the drive itself handles returned energy, and its over-voltage threshold, are TBD.
Wire the CAN bus
host adapter ──── drive 1 ──── drive 2 ──── ... ──── drive N
120 Ω 120 Ω
- Wire the bus as a single line from the first node to the last. Do not wire a star.
- Use twisted pair for CAN_H and CAN_L.
- Connect CAN ground between all nodes.
- Keep stubs, the short branches from the bus line to a node, as short as you can.
- Fit one 120 Ω resistor between CAN_H and CAN_L at each physical end of the line. Fit no termination on nodes in between.
Check the termination
With every node unpowered, measure the resistance between CAN_H and CAN_L at any node.
| Reading | Meaning |
|---|---|
| about 60 Ω | Correct: two 120 Ω terminators. |
| about 120 Ω | One terminator is missing. |
| about 40 Ω | Three terminators are fitted. |
| close to 0 Ω | CAN_H and CAN_L are shorted. |
| open circuit | No terminators, or a broken wire. |
Bit rates
- Every node on a bus must use the same arbitration bit rate. On CAN FD, every node must also use the same data bit rate.
- Use the same sample points on every node. The drive's sample points: TBD.
- The drive's factory bit rates are TBD. To change them, see Configuration.
- Do not connect a classic CAN controller that is not CAN FD tolerant to a bus that carries CAN FD frames. It treats each CAN FD frame as an error and disturbs the bus.
To set up the host side, see CAN FD on Linux.
Node IDs
Each drive on a bus needs its own node ID. CANopen allows node IDs 1 to 127. The factory node ID is TBD. If every drive leaves the factory with the same node ID, set a new ID on each drive before you connect the next one. See Configuration.
Safe torque off
The drive has a hardware safe torque off (STO) function. It is designed toward IEC 61800-5-2 and is not certified. Not defined yet: input type, voltage levels, number of channels and response time. Read Safety before you use it in a device.