Electrical and CAN wiring

Last updated 2026-11-27

This page covers the 48 V supply, the CAN bus wiring and the safe torque off input. The connector and pin-out are not defined yet.

Electrical interface

Item Value
Supply voltage, nominal 48 V DC
Supply voltage range TBD
Supply current, continuous and peak TBD
Power connector TBD
Signal connector TBD
CAN CAN FD; classic CAN at 1 Mbit/s
CAN FD data bit rate TBD
Built-in CAN termination TBD
Safe torque off input Electrical interface TBD. Designed toward IEC 61800-5-2, not certified.
HVIL connector One 2-pin connector: loop IN and loop OUT. PWM signal, daisy-chained through all drives. Part TBD. See Interlock loop (HVIL).

Pin-out

Signal Connector Pin
Supply + (48 V) TBD TBD
Supply − (0 V) TBD TBD
CAN_H TBD TBD
CAN_L TBD TBD
CAN ground TBD TBD
HVIL loop IN HVIL connector, pin TBD TBD
HVIL loop OUT HVIL connector, pin TBD TBD
Safe torque off TBD TBD
Cable shield TBD TBD

Connect the supply

  1. Switch the supply off.
  2. Fit a fuse in the positive line, close to the supply. Fuse rating: TBD.
  3. Connect the drive.
  4. Switch the supply on.

Do not plug the drive into a supply that is already on.

Energy returned to the supply

When the joint is back-driven, or when the drive brakes the joint, the motor acts as a generator and returns energy to the 48 V line. A bench supply that cannot sink current lets the line voltage rise. Use one of these:

How the drive itself handles returned energy, and its over-voltage threshold, are TBD.

Wire the CAN bus

 host adapter ──── drive 1 ──── drive 2 ──── ... ──── drive N
   120 Ω                                               120 Ω
  1. Wire the bus as a single line from the first node to the last. Do not wire a star.
  2. Use twisted pair for CAN_H and CAN_L.
  3. Connect CAN ground between all nodes.
  4. Keep stubs, the short branches from the bus line to a node, as short as you can.
  5. Fit one 120 Ω resistor between CAN_H and CAN_L at each physical end of the line. Fit no termination on nodes in between.

Check the termination

With every node unpowered, measure the resistance between CAN_H and CAN_L at any node.

Reading Meaning
about 60 Ω Correct: two 120 Ω terminators.
about 120 Ω One terminator is missing.
about 40 Ω Three terminators are fitted.
close to 0 Ω CAN_H and CAN_L are shorted.
open circuit No terminators, or a broken wire.

Bit rates

To set up the host side, see CAN FD on Linux.

Node IDs

Each drive on a bus needs its own node ID. CANopen allows node IDs 1 to 127. The factory node ID is TBD. If every drive leaves the factory with the same node ID, set a new ID on each drive before you connect the next one. See Configuration.

Safe torque off

The drive has a hardware safe torque off (STO) function. It is designed toward IEC 61800-5-2 and is not certified. Not defined yet: input type, voltage levels, number of channels and response time. Read Safety before you use it in a device.